ASI IO SL DO 44 AS-Interface (AS-i) Module With 4 Digital Outputs Data Sheet 6111B 01/2002 6 1 0 9 A 0 0 0 Function This module is used to output digital signals. Features - Four digital signal outputs, each with a load capacity of 0.5 A - Compact design - Can be mounted in various positions - Indication of AS-i voltage - Indictaion of external auxiliary power - Outputs and sensor supply electronically protected against short-circuits and overloads - Single slave 6111B 6 1 0 9 B 0 0 1 Figure 1 Module view 1 ASI IO SL DO 44 Diagnostic and Status Indicators Des. Color Meaning AS-i Green Bus voltage available Y Y AUX Green Supply voltage of the outputs 1 YY Yellow Status of the outputs Y Y The module is functioning correctly if all of the green LEDs are on. Y Y 1 Connections Y Y A S -I A U X 6 1 1 1 B 0 0 3 Figure 2 Indicators and connections Connection Assignment 1 Outputs 1 to 4 Pin Assignment of Outputs Pin Outputs 1 Not used 3 0V 4 Output Pin Assignment of AS-i/Supply Voltage 6 1 0 9 A 0 0 4 Figure 3 Pin assignment of outputs Pin Assignment 1 AS-i + 2 0V 3 AS-i - 4 +24 V 6 1 0 9 A 0 1 5 Figure 4 2 Pin assignment of AS-i/ supply voltage 6111B ASI IO SL DO 44 Internal Circuit Diagram Key: A S I 3 + Protocol chip Amplifier Optocoupler A S I 3 + Status LED Digital Output 4 6 1 1 1 B 0 1 0 Figure 5 6111B Internal wiring of the module 3 ASI IO SL DO 44 Installing the Module Installing the Module A * Screw the module directly onto a flat mounting surface. * The bottom (A) or the side (B) of the module can be the mounting surface. * Connect the AS-i bus and the power supply to the M12 connector. For example, use the connecting cable, Order No. 27 41 19 2. B 6 1 0 9 A 0 0 5 Figure 6 Installing the module Connecting the AS-i and the Voltage Supply 6 1 0 9 A 0 0 6 Figure 7 4 Connecting the AS-i and the voltage supply 6111B ASI IO SL DO 44 Connecting Actuators * Connect your actuators to the desired outputs (M8 connections). Screw a protective cap (Order No. 18 82 54 0, some are supplied as standard) onto the connectors that are not being used. 6 1 0 9 A 0 0 7 Figure 8 Connecting the actuators Connection Example Connection Notes Use PELV power supply O U T 1 O U T 2 O U T 3 O U T 4 The auxiliary supply voltage for the supply of the outputs must be tapped from an isolated power supply (PELV according to IEC 60364-4-41). 6 1 1 1 B 0 1 1 Figure 9 6111B Typical actuator connection 5 ASI IO SL DO 44 Programming Data Configuration Data I/O code 8hex (8dec) ID code 0hex (0dec) AS-i specification 2.0 (single slave) Data Bit (Output Via AS-i) Bit Function D0 Output OUT1 D1 Output OUT2 D2 Output OUT3 D3 Output OUT4 Parameter Bit (Programmable Using AS-i) Bit Function P0 Not used P1 Not used P2 Not used P3 Not used 6 6111B ASI IO SL DO 44 (3 .4 8 4 ") 7 9 ,5 m m (3 .1 3 0 ") 2 6 m m (1 .0 2 4 ") (0 .1 5 7 ") (0 .1 5 7 ") 8 8 ,5 m m 2 6 m m (1 .0 2 4 ") 4 m m 4 m m Technical Data 6 1 0 9 B 0 1 2 Figure 10 Dimensions of the module and mounting plate General Data Order Designation ASI IO SL DIO 4/4 Order No. 27 41 12 1 Housing dimensions (width x height x depth) 26 mm x 26 mm x 88.5 mm (1.024 in. x 1.024 in. x 3.484 in.) Housing material PBT Weight (typical) Approximately 100 g Permissible temperature (operation) -25C to +70C (-13F to +158F) Permissible temperature (storage/transport) -25C to +85C (-13F to +185F) Degree of protection according to IEC 60529 IP 67 Degree of protection according to IEC 60536 (VDE 0106) Class of protection III Operating voltage Protected against polarity reversal from the AS-interface Maximum operating current 50 mA 6111B 7 ASI IO SL DO 44 Connections AS-interface and external auxiliary power M12 male connector Outputs M8 female connector Digital Outputs Status indicator LED (yellow) Number 4 Connection method for actuators Two-wire technology Minimum output voltage UAux = - 0.5 V Nominal current per output 0.5 A Total current per module 3A ON delay time 1 ms OFF delay time 1 ms Derating No Permissible load per output Ohmic load 12 W Inductive load 12 VA Lamp load 12 W Permissible switching frequency with Ohmic load 0 kHz to 1 kHz Inductive load 0 Hz to 1 Hz Lamp load 0 Hz to 10 Hz Limitation of the voltage induced on circuit inter- Yes ruption Protective function Short-circuit-proof Approvals CE Yes AS-i certification Yes 8 6111B ASI IO SL DO 44 Conformance With EMC Directive 89/336/EEC Noise Immunity Test According to EN 50082-2:1995 Electrostatic discharge (ESD) EN 61000-4-2:1995/ IEC 61000-4-2 Criterion B 6 kV contact discharge 8 kV air discharge Electromagnetic fields EN 61000-4-3:1993/ IEC 61000-4-3 Criterion A Field strength: 10 V/m Fast transients (burst) EN 61000-4-4:1995/ IEC 61000-4-4 Criterion B Supply lines: 2 kV Signal/data lines: 2 kV Conducted interference EN 61000-4-6:1993/ IEC 61000-4-6 Criterion A, test voltage 7 V Criterion B, test voltage 10 V Functional reliability can be reduced by the influence of conducted interference caused by high-frequency fields. Noise Emission Test in Accordance With EN 50081-2:1993 Noise emission of housing 6111B EN 55011:1991 Class A 9 ASI IO SL DO 44 Description Order Designation Order No. AS-interface (AS-i) module with 4 digital outputs ASI IO SL DO 44 27 41 12 1 Connecting cable 1 m with connection for two ASI CC CAB SL FCAB PWR round cables 27 41 19 2 AS-Interface passive distributor quintuple M12 ASI CC DIST FCAB 5M12 27 41 47 7 Protective caps for replacement (for unused connections) PROT-M8 16 82 54 0 Markers pack of 10 ZB 5/M8:UNBEDRUCKT 5 16 99 94 4 Sensor cable for addressing the S Line modu- SAC-4P-M12MS/ 0,6-PUR/ les (0.6 m) M12FS 16 68 36 0 Addressing device 27 41 33 8 ASI CC ADR Additional accessories for connecting the actuators can be found in the Phoenix Contact PLUSCON catalog. Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + 49 - (0) 52 35 - 3-00 + 49 - (0) 52 35 - 3-4 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork 10 6111B (c) Phoenix Contact 01/2002 Technical modifications reserved TNR 90 03 55 4 Ordering Data